UL 62368-1 Test Report vs UL Listed: What Amazon Sellers Should Know
Published · Updated
By Jayden Liang, Sales Manager, LONGRICH POWER
Suppliers often say a product has a “UL report”. That usually means a test report to a UL standard, which is not the same as a UL Listing. The difference decides what you can say on your listing, what you can show in a compliance review and what your retailer will accept.
Short answer: a UL 62368-1 test report shows that samples of one model were tested to the standard by a laboratory. UL Listed means UL Solutions certified the product, authorized the UL Mark and keeps inspecting the factory. Where a LONGRICH model has UL 62368-1 documentation, it is a test report, not a Listing. None of our products are UL Listed, so they must not carry the UL Mark or be described as UL Listed.
Test Report vs. UL Listing at a Glance
UL 62368-1 test report
UL Listed
What it is
A laboratory’s record that submitted samples of one model were tested to UL 62368-1
A certification: UL Solutions evaluated the product and authorized the UL Listing Mark
Who issues it
Any testing laboratory, including independent third-party labs
UL Solutions (other NRTLs, such as ETL or CSA, issue their own Listing marks)
What it covers
The samples and the model or configuration named in the report
The Listed product, as recorded in UL Solutions’ certification directory
Ongoing checks
None after the report is issued
Follow-Up Services: factory inspections confirm production still matches the certified product
Mark on the product
No UL Mark may be used
UL Listing Mark with the product name and a control or file number
How a buyer verifies it
Read the report: model numbers, standard, applicant, lab, date and ratings
Look up the product in UL Solutions’ certification directory
Typical use
Supplier due diligence and marketplace document reviews
Retail, distribution or workplace channels that require a certified product
UL Solutions is one of several Nationally Recognized Testing Laboratories (NRTLs) recognized by OSHA. Each NRTL uses its own registered certification mark, so an ETL or CSA Listing plays the same role as a UL Listing for most buyers.
What This Means for Your Amazon Listing
Documents follow the category
Amazon sets document requirements by product category and shows them in Seller Central. For many plug-in electrical products, sellers are asked for a safety test report to the applicable standard from a third-party laboratory, often one accredited to ISO/IEC 17025. Requirements change, so check what is shown for your listing.
Details must match
Reviews compare the report with the listing. The model number, brand, ratings and product photos should match what the report describes. A report for a similar model, or for a different plug or USB configuration, is a common reason for rejection.
Say “tested to”, not “Listed”
With a test report you can say the product was tested to UL 62368-1 and share the report when asked. Do not write “UL Listed” or “UL certified” in titles, bullets or images, and do not use the UL logo.
Some channels need a Listing
Retailers, distributors and workplace buyers may require a Listing from an NRTL. US power strips are usually evaluated under UL 1363 rather than UL 62368-1; see our US power strip market guide.
Which LONGRICH Models Have UL 62368-1 Test Reports
Reports are issued by independent third-party labs and are model-specific. We confirm which report matches your exact configuration and destination before you order, and we share the report to support your compliance review. None of these products are UL Listed, and we hold no UL 1363 reports.
No UL test report; documentation confirmed per project
Models not listed here: ask us. Documentation is confirmed per model and configuration before quotation.
How to Read a Supplier’s Test Report
Check
What to look for
Model numbers
Your exact SKU is named in the report, or the report explains how the variant is covered
Standard
The report is to UL 62368-1, the standard your category asks for, and not a different one
Laboratory
Which lab issued it, and whether that lab’s accreditation covers this standard (marketplaces often ask for ISO/IEC 17025)
Applicant and manufacturer
Company names are consistent with the supplier you buy from
Ratings
Input, output and USB ratings in the report match your listing and packaging
Construction
Photos and parts lists match the units you will receive; a change to the plug, USB circuit or enclosure may need new testing
Date
The report is current for the production you are buying
Get the Right Report Before You List
Tell us your model, destination market and marketplace, and we will confirm which test report covers your configuration before quotation.
MOQ is 1,000 pcs per model, including existing models with your logo and neutral packaging. Models can be mixed in one order at 1,000 pcs or more per model. Stock samples ship in about 3 days.
Is a UL 62368-1 test report the same as UL Listed?
No. A test report records that samples of a specific model were tested to UL 62368-1 by a laboratory. UL Listed means UL Solutions certified the product, authorized the UL Listing Mark and keeps checking production through factory follow-up inspections. A product with only a test report is not UL Listed and must not carry the UL Mark.
Can I write “UL certified” or “UL Listed” on my Amazon listing if I have a test report?
No. With a test report you can say the product was tested to UL 62368-1, and share the report when asked. Words such as “UL Listed” or “UL certified”, or the UL logo in images, describe a certification the product does not have.
Will Amazon accept a UL 62368-1 test report?
Amazon sets document requirements by product category and shows them in Seller Central, and they change over time. For many plug-in electrical products, sellers are asked for a safety test report to the applicable standard from a third-party laboratory, often one accredited to ISO/IEC 17025. Check the requirement shown for your listing and make sure the model, brand and ratings in the report match it.
Which LONGRICH models have UL 62368-1 test reports?
NT009-ALL, NT009-EU and NT009-AUS (NT009 platform report), NT011-US and NT011-ALL (NT011-US report), NT010 and NT010-G (NT010 report), WPG-US012-7, WPG-US012-9C, WPG01, WPG05, TUS-2F, TUS-8, TUS-8B, TUS-9, TUS-11 and TUS-13. TUS-4, ECS-US013 and ECS-US019 do not have UL test reports. None of our products are UL Listed.
Do you have UL 1363 reports for power strips?
No. Our reports are to UL 62368-1, and we hold no UL 1363 evaluations or Listings. If your retailer or channel requires UL 1363 or a UL or ETL Listing for a power strip, we arrange that project with you for the final configuration.